Specifications:
1)Galvanic isolation 2000VAC
2)Operation: HART-protocol
3)PC programmable temperature transmitter for converting various input signals into a scalable 4 to 20mA analogue output signal
4)Wide voltage supply range
5)Expanded resistance input (max 2kΩ)
6)Expanded voltage input (max 2KmV)
Performance:
* Internal cold junction
* Fault signal on sensor break or short circuit
* 2-wire technology, 4 to 20mA analogue output
* High accuracy in total ambient temperature range
* Customer specific measurement range setting or expanded SETUP
| Technical data: |
| Output: | 4 to 20mA |
| Supply voltage: | 7.5 to 45VDC |
| Input: | RTD, TC, Ohm, mV |
| Influence of ambient: | Negligible |
| Load influence: | Negligible |
| Power supply influence: | Negligible |
| Resolution: | 0.3uA |
| Installation: | sensor head Form B |
| Operation: | PC-programmable |